ID: 61
Category:
application-notes
ESI System:
SampleSense Oil
Application:
Oils, Lubricants & Coolants
The SampleSense Oil system provides high throughput, controlled sample mixing, positive confirmation of sample introduction and sample position, autosampler autocorrection, compatibility with multiple vial sizes, and stable performance, all while achieving three samples per minute.
ID: 67
Category:
application-notes
ESI System:
prepFAST X, DXCi autocorrecting autosampler
Application:
Oils, Lubricants & Coolants
prepFAST X highly automates ICP engine coolant analyses through high-speed in-line syringe-driven dilution. prepFAST X includes four inert syringes coupled to a SampleSense X valve having integrated samplesensing technology. The system also includes a DXCi autocorrecting autosampler with position detection and autocorrection capability. After sensing and preparing each sample, prepFAST X triggers the ICP read to complete the analysis.
ID: 68
Category:
application-notes
ESI System:
SampleSense Oil
Application:
Oils, Lubricants & Coolants
The SampleSense Oil system for Agilent 5900 ICP-OES provides ultrahigh throughput analysis for in-service oil laboratories running ASTM Method D5185. The SampleSense Oil system provides in-service lubricant laboratories an entirely new level of performance. SampleSense Oil combines ultra-high throughput ICPOES analysis, minimizes ICP system maintenance, maximizes profit per sample and provides significantly improved data.
ID: 77
Category:
application-notes
ESI System:
SampleSense Oil
Application:
Oils, Lubricants & Coolants
SampleSense Oil provides a fast, accurate sample introduction system that incorporates a gas infusion mixing. This provides controlled sample mixing to homogenize the sample immediately before analysis, eliminating manual mixing of samples after dilution and resulting in significant time savings and improved productivity.
ID: 78
Category:
application-notes
ESI System:
SampleSense Oil
Application:
Oils, Lubricants & Coolants
SampleSense Oil provides a fast, accurate sample introduction system that incorporates a gas infusion mixing. This provides controlled sample mixing to homogenize the sample immediately before analysis, eliminating manual mixing of samples after dilution and resulting in significant time savings and improved productivity.
ID: 241
Category:
application-notes
ESI System:
prepMASS Station
Application:
Oils, Lubricants & Coolants
prepMASS automatically dilutes oil and lubricant samples by weight for elemental ICP analysis. Using inert syringe technology, samples are precisely prepared from the source sample containers into the final diluted sample vials by means of an integrated and fully automated balance. Carryover is eliminated using disposable pipette tips and liquid level sensing for highly accurate and precise dilutions for a wide range of sample types. Upon completion of the weight dilution, a second transfer arm delivers the vial to the analysis rack and the dilution data is recorded.
ID: 317
Category:
application-notes
ESI System:
SampleSense Oil
Application:
Oils, Lubricants & Coolants
SampleSense Soil uses an inert injection valve with built-in optical sensors that automatically detect the liquid sample, inject the valve and trigger the ICP read in a tightly-timed analytical sequence. SampleSense Soil eliminates wasted time from the ICP method and can more than double sample throughput on the iCAP ICPOES while recording missing or empty tubes.